The high performance liquid chromatography Diaries
The high performance liquid chromatography Diaries
Blog Article
크로마토그래피 원리의 큰 틀도 마찬가지로 두 상에 대한 분배 차이를 이용하여 분석물을 분리, 정제할 수 있습니다. 다만 크로마토그래피에서 두 개의 상은 하나는 고정하고 다른 하나는 일정 방향으로 이동시켜 사용합니다.
High performance liquid chromatography or typically often called HPLC is definitely an analytical system utilized to different, recognize or quantify Each individual component in a mix.
Adsorption chromatography requires the interaction of chemicals Using the surface with the stationary phase. A compound’s affinity for that stationary stage determines its diploma of retention. In reverse-stage HPLC, one example is, nonpolar molecules are held by a polar stationary period.
Decreasing the level of acetonitrile and increasing the amount of water within the mobile will enhance retention times, furnishing more time for you to impact a separation.
In reversed-phase HPLC the buy of elution is the other that in a normal-period separation, with far more polar solutes eluting first. Rising the polarity from the mobile stage causes lengthier retention times. Shorter retention times need a mobile section of reduced polarity.
1. The strong-phase extraction is important because it gets rid of constitutions within the serum that might interfere with the Evaluation. What forms of interferences are possible?
The detector screens the eluent and generates a sign, that is usually in the form of the chromatogram, which is a graphical illustration of compound concentration with time.
前述した従来の順相タイプに対して、逆相クロマトグラフィーにおいては固定相に低極性のもの(例えばシリカゲルにアルキル基を共有結合させたもの)を、移動相に高極性のもの(例えば水や塩類の水溶液、アルコール、アセトニトリルなどの有機溶媒)を用いる。また珍しいケースではあるが、分離のための移動相pHをシリカゲルの使用範囲から外れたところに設定する必要がある場合、あるいはシリカゲル表面に残っている未反応シラノール基が分離に悪影響を及ぼし、かつそれが移動相の変更によっても解決できない場合には、固定相として樹脂を用いることがある。分析物はより極性の低いほどより強く固定相と相互作用して溶出が遅くなる。また極性の低い物質の割合が多い移動相ほど溶出が早くなる。
스포츠 도핑에서 약물 검사까지 법의독성학 응용 분야에 적용되는 방법에 대해 알아보세요.
충전제는 실리카겔 혹은 중합체의 미세입자로 표면에 화학 수식이 되어 있는 경우가 대부분이며 여러 종류가 있습니다.
Sample injection introduces the geared up sample in to the HPLC system. The injection quantity and procedure can drastically influence:
In this particular portion we consider the basic plumbing necessary to transfer the cell phase from the column also to inject the sample into your cellular phase.
The elution buy of solutes in HPLC is ruled by polarity. For a standard-stage separation, a solute of decrease polarity spends proportionally fewer time during the polar stationary section and elutes just before a solute that's extra polar. Given a particular stationary section, retention times in regular-stage HPLC are managed by changing the cellular phase’s Attributes. One example is, Should the resolution concerning two solutes is very poor, switching into a less polar read more mobile stage retains the solutes about the column for a longer time and gives read more extra chance for his or her separation.
The injector introduces a exact volume of the sample solution in to the cellular phase stream. Quite a few injection procedures exist, with loop injection getting a typical procedure.